• 0977-XXX-XXXX
  • constructph021@gmail.com
  • Quezon City, Philippines
Pricelist
Air Damper Guaranteed Best Construction Material Philippines’ Prices

Air Damper Guaranteed Best Construction Material Philippines’ Prices

What does such a air damper mean?

In order to control or stop the flow of air through a duct, chimney, variable-air-volume (VAV) box, air-handling unit, or other similar pieces of equipment, a device known as an air damper is used.

In rooms where air conditioning is not necessary, dampers are also used to stop airflow. Additionally, dampers can be utilized as fire or smoke protection systems.

A sophisticated system with numerous moving parts is an air damper. The blades are their main part, and they move them to change the airflow.

Dampers also include, among other things, frames, linkages, axles, bearings, seals, blade pins, actuation motors, flanging, jackshafts, and sleeves.

Types of Air Dampers

Air dampers can be divided into parallel blade and opposing blade types based on how they are built. Each configuration is designed for a different application and has distinct performance characteristics.

damper

1. Parallel Blade Dampers

The blades of this style of air damper rotate in unison and perpendicular to one another.

When the damper has two operating states—open or closed—parallel blade design is commonly used.

As they transition from fully open to closed, these dampers reroute air flow through the first few degrees of rotation; as a result, control is obtained during the first 20–30% of movement.

These dampers modify the direction of air streams rather than modulating them, which is primarily why they are recommended for open-close operation or fixed flow control.

In applications where the damper accounts for a significant fraction of the overall system pressure loss, parallel blade dampers are frequently used.

Due to their unequal airflow, they shouldn’t be employed upstream of crucial components.

2. Opposed Blade Dampers

This kind of air damper modulates airflow by having the blades rotate in opposition to one another.

These air dampers can also be utilized for on-off service, however they are typically used when the system needs airflow control rather than open-close operation.

The following applications are typical uses for opposed blade dampers:

  • When the total system pressure loss is not primarily attributable to the damper.
  • Systems that are necessary to keep the airflow consistent downstream from the damper.
  • Terminals with ducts.

The table below shows the latest retail March 2024 prices of Air Dampers in Philippine Peso price per pieces including its standard sizes and various thickness

Price and Standard Sizes of Air Damper per pc in the Philippines

DESCRIPTIONWIDTHHEIGHTPRICE
Damper , Manual Volume Control250.00250.00900.00
Damper , Manual Volume Control500.00400.002050.00
Damper , Manual Volume Control550.00350.002150.00
Damper , Manual Volume Control850.00600.005500.00
Damper , Manual Volume Control1200.00850.0010500.00
Damper, Back Draft350.00250.001000.00
Damper, Back Draft400.00400.002050.00
Damper, Back Draft650.00550.004150.00
Damper, Fire200.00200.00900.00
Damper, Fire250.00200.00850.00
Damper, Fire250.00250.00900.00
Damper, Fire350.00250.001000.00
Damper, Fire400.00400.001600.00
Damper, Fire550.00450.002450.00
Damper, Fire1200.00800.009800.00
Damper, Fire1800.00600.0016000.00
Damper, Fire1900.001900.0052000.00
Damper, Motorized600.00450.005000.00
Damper, Motorized1200.00850.0013500.00
Damper, Motorized1450.002100.0038000.00
Damper, Motorized5700.001900.00120000.00
Price and Standard Sizes of Air Damper per pc in the Philippines

UPDATED: Construction Material Prices for Air Dampers in the Philippines (March 2024)

UPDATED: All Construction Prices are based on retail prices around hardware in Metro Manila

To see other material construction, please see here.

To know other construction guides, tips and methodology for beginners, veterans and contractors, please see here.

Leave a Reply

Your email address will not be published. Required fields are marked *